Schneider Electric Zelio Logic Compact Smart Relay 20 I/O 24V DC Clock Display SR2B202BD
(Price Includes VAT)
Order Now & Get it by 2 days
Sold by: Marketplace
Brand : Schneider Electric
Type : Compact Smart Relay
Description
Schneider Electric SR2B202BD Compact Smart Relay is part of Zelio Logic SR2/SR3, an offering of simple automation systems with 10 to 40 I/O. This compact smart relay from Zelio Logic features 20 I/O, local display, 0 to 240 with a ladder diagram, and 0 to 500 with FBD programming control lines. It is a module with a nominal supply voltage of 24 V DC and a cycle time of 6 ms to 90 ms.
Schneider Electric SR2B202BD Zelio Logic Compact Smart Relay offers 12 discrete ohmic inputs with a voltage of 24 V DC, 6 analog input ranges from 0 V to 10 V, 0 V to 12 V, and 8 transistor outputs with a voltage of 24 V. It has IP20 and IP40 protection. It weighs 0.28 kg. The main application area of this module is industry and the construction/service sector. It is certified by C-Tick, GL, UL, CSA, and GOST. Complies with EN/IEC 60068-2-6 Fc and EN/IEC 61000-4-11 standards. Zelio Logic is easy to use and offers a real alternative solution based on hardwired logic or specific cards.
Features
- It features 20 I/O, local display, 0 to 240 with a ladder diagram, and 0 to 500 with FBD programming control lines.
- It is a module with a nominal supply voltage of 24 V DC and a cycle time of 6 ms to 90 ms.
- IP20 and IP40 protection
Brand | Schneider Electric |
Item Name | Compact Smart Relay |
Model | SR2B202BD |
Rated Supply Voltage | 24 V DC |
Ambient Air Temperature For Storage | -40-70 °C |
Connections - Terminals | Screw terminals, 1 x 0.2...1 x 2.5 mm² (AWG 25...AWG 14) semi-solid, screw terminals, 1 x 0.2...1 x 2.5 mm² (AWG 25...AWG 14) solid, screw terminals, 1 x 0.25...1 x 2.5 mm² (AWG 24...AWG 14) flexible with cable end, screw terminals, 2 x 0.2...2 x 1.5 mm² (AWG 24...AWG 16) solid, screw terminals, 2 x 0.25...2 x 0.75 mm² (AWG 24...AWG 18) flexible with cable end |
IP Degree Of Protection | IP20 (terminal block) conforming to IEC 60529, IP40 (front panel) conforming to IEC 60529 |
Load Current | 0.5-0.625 A transistor output |
Operating Altitude | 2000 m |
Output Voltage | 24 V transistor output |
Output Voltage Limits | 19.2...30 V DC (transistor output) |
Overvoltage Category | III conforming to EN/IEC 60664-1 |
Pollution Degree | 2 Conforming to EN/IEC 61131-2 |
Power Dissipation in W | 3 W without extension |
Tightening Torque | 0.5 N.m |
Certifications | GOST, UL, CSA, C-Tick, GL |
Range Of Product | Zelio Logic |
Relative Humidity | 95-95 % without condensation or dripping water |
Short-circuit Protection | With transistor output |
Supply Voltage Limits | 19.2-30 V |
Contacts Type And Composition | NO for relay output |
Number Or Control Scheme Lines | 0-240 with ladder programming, 0-500 with FBD programming |
Clock Drift | 12 min/year at 0-55 °C, 6 s/month at 25-25 °C |
Immunity To Microbreaks | 1 ms |
Discrete Input Current | 4 mA |
Current State 1 Guaranteed | >= 1.2 mA (IB...IG used as discrete input circuit), >= 2.2 mA (I1...IA and IH...IR discrete input circuit) |
Voltage State 1 Guaranteed | >= 15 V for I1...IA and IH...IR discrete input circuit, >= 15 V for IB...IG used as discrete input circuit |
Maximum Altitude Transport | 3048 m |
Cycle Time | 6-90 ms |
Checks | Program memory on each power-up |
Disturbance Radiated/conducted | Class B conforming to EN 55022-11 group 1 |
Output Thermal Current | 8 A for all 4 outputs for relay output |
Discrete Input Voltage | 24 V DC |
Backup Time | 10 years at 25 °C |
Clock | With |
Local Display | With |
Voltage State 0 Guaranteed | <= 5 V for I1...IA and IH...IR discrete input circuit, <= 5 V for IB...IG used as discrete input circuit |
Current State 0 Guaranteed | <= 0.5 mA (IB...IG used as discrete input circuit), <= 0.75 mA (I1...IA and IH...IR discrete input circuit) |
Discrete Input Number | 12 conforming to EN/IEC 61131-2 type 1 |
Input Compatibility | 3-wire proximity sensors PNP for discrete input |
Discrete Input Type | Resistive |
Temperature Probe Type | NTC 10k at 25 °C, NTC 1000k at 25 °C, KTY81 210/220/221/222/250, Pt 500 |
Input Compatibility | 3-wire proximity sensors PNP for discrete input |
Discrete Input Type | Resistive |
Analogue Input Resolution | 8 bits |
Analogue Input Number | 6 |
Analogue Input Type | Common Mode |
Repeat Accuracy | +/- 2 % at 55 °C for analogue input circuit |
Conversion Error | +/- 5 % at 25 °C for analogue input circuit, +/- 6.2 % at 55 °C for analogue input circuit |
LSB Value | 39 mV for analogue input circuit |
Reverse Polarity Protection | With |
Maximum Permissible Voltage | 30 V for analogue input circuit |
Analogue Input Range | 0...10 V, 0...24 V |
Conversion Time | Smart relay cycle time for analogue input circuit |
Operating Distance | 10 m between stations, with screened cable (sensor not isolated) for analogue input circuit |
Counting Frequency | 1 kHz for discrete input |
Overvoltage Protection | With overvoltage protection for transistor output |
Residual Voltage | 2 V at state 1 transistor output |
Ambient Air Temperature For Operation | -20-40 °C in non-ventilated enclosure conforming to IEC 60068-2-1 and IEC 60068-2-2, -20-55 °C conforming to IEC 60068-2-1 and IEC 60068-2-2 |
Standards | EN/IEC 61000-4-4 level 3, EN/IEC 60068-2-27 Ea, EN/IEC 61000-4-5, EN/IEC 61000-4-6 level 3, EN/IEC 61000-4-11, EN/IEC 61000-4-2 level 3, EN/IEC 61000-4-3, EN/IEC 61000-4-12, EN/IEC 60068-2-6 Fc |
Environmental Characteristic | EMC directive conforming to EN/IEC 61000-6-2, EMC directive conforming to EN/IEC 61000-6-3, EMC directive conforming to EN/IEC 61000-6-4, EMC directive conforming to EN/IEC 61131-2 zone B, low voltage directive conforming to EN/IEC 61131-2 |
Input Impedance | 12 kOhm for IB...IG used as analogue input circuit, 12 kOhm for IB...IG used as discrete input circuit, 7.4 kOhm for I1...IA and IH...IR discrete input circuit |
Weight | 0.28 kg |