Schneider Electric TeSys K Contactor 4P(4NO) AC-1 <= 440V 20A 24V AC Standard Coil LC1K09004B7

AED 116.55

(Price Includes VAT)

Delivery truck icon

Order Now & Get it by 2 days

Shop logo

Sold by: Marketplace

Free delivery inside Dubai on all orders with no order limit. Pay in 4 interest-free installments for Dubai orders using Tabby.
Cash on delivery payment method icon
Cash on Delivery
7 Days Returnable icon
7 Days Returnable
15+ Years Of Trust icon
15+ Years Of Trust
15+ Branches icon
15+ Branches
Quantity

Brand : Schneider Electric

Type : Contactor

Collections

Description

Schneider Electric LC1K09004B7 TeSys K Contactor, 4 poles (4 NO), for non-inductive load control applications up to 20 A/690 V AC-1. It has a 24 V AC coil at 50/60 Hz, without built-in auxiliary contact and connection via screw terminals. For operating rates up to 600 cycles/hour and environments up to 50°C, it ensures reliability and durability in standard applications. Very compact (45mm wide), DIN rail mounting or screw mounting. Multi-standard certification (IEC, UL, CSA, CCC, EAC), Green Premium compliant (RoHS/REACh).

Features
  • 20A TP AC1 Contactor AC1 24V AC Coil
  • Used to make or break an electrical connection
  • 4-pole contactor for connection by screw clamp terminals
Specifications
Brand Schneider Electric
Item Name Contactor
Model LC1K09004B7
Conventional Free Air Thermal Current 20 A (at 50 °C) for power circuit
Control Circuit Voltage 24 V AC 50/60 Hz
Rated Insulation Voltage Power Circuit: 600 V conforming to UL 508, power circuit: 690 V conforming to IEC 60947-4-1, power circuit: 600 V conforming to CSA C22.2 No 14
Rated Impulse Withstand Voltage 8 kV
Ambient Air Temperature For Storage -50-80 °C
Associated Fuse Rating 25 A gG at <= 440 V for power circuit, 25 A aM for power circuit
Average Impedance 3 mOhm - Ith 20 A 50 Hz for power circuit
Compatibility Code LC1K
Connections - Terminals Screw clamp terminals 2 cable(s) 4-4 mm²solid, screw clamp terminals 2 cable(s) 4-4 mm²flexible without cable end, screw clamp terminals 2 cable(s) 1.5-1.5 mm²flexible with cable end
Contactor Application Resistive Load
Control Circuit Type AC at 50/60 Hz
Control Circuit Voltage Limits Operational: 0.8...1.15 Uc (at <50 °C), drop-out: 0.2...0.75 Uc (at <50 °C)
Flame Retardance V1 conforming to UL 94, requirement 2 conforming to NF F 16-101, requirement 2 conforming to NF F 16-102
Depth 57 mm
Device Application Control
Heat Dissipation 1.3-1.3 W
Height 58 mm
Hold-in Power Consumption in VA 4.5-4.5 VA (at 20 °C)
Inrush Power in VA 30-30 VA (at 20 °C)
Insulation Resistance > 10 MOhm for Signalling Circuit
Irms Rated Making Capacity 110 A AC for power circuit conforming to NF C 63-110, 110 A AC for power circuit conforming to IEC 60947
Maximum Operating Rate 3600 cyc/h 60 °C
Mechanical Durability 10 Mcycles
Mechanical Robustness Shocks contactor closed, on X axis: 10 Gn for 11 ms conforming to IEC 60068-2-27, shocks contactor closed, on Y axis: 15 Gn for 11 ms conforming to IEC 60068-2-27, shocks contactor closed, on Z axis: 15 Gn for 11 ms conforming to IEC 60068-2-27, shocks contactor opened, on X axis: 6 Gn for 11 ms conforming to IEC 60068-2-27, shocks contactor opened, on Y axis: 10 Gn for 11 ms conforming to IEC 60068-2-27, shocks contactor opened, on Z axis: 10 Gn for 11 ms conforming to IEC 60068-2-27, vibrations contactor closed: 4 Gn, 5...300 Hz conforming to IEC 60068-2-6, vibrations contactor opened: 2 Gn, 5...300 Hz conforming to IEC 60068-2-6
Mounting Support Rail, Plate
Operating Altitude 2000 m without derating
Operating Time 10...20 ms coil de-energisation and NO opening, 10...20 ms coil energisation and NO closing
Overvoltage Category III
Pole Contact Composition 4NO
Poles Description 4P
Certifications CB Scheme, CCC, UL, CSA, EAC, CE, UKCA
Protective Treatment TC conforming to IEC 60068, TC conforming to DIN 50016
Range TeSys K
Rated Breaking Capacity 110 A at 415 V conforming to IEC 60947, 110 A at 440 V conforming to IEC 60947, 80 A at 500 V conforming to IEC 60947, 110 A at 220...230 V conforming to IEC 60947, 110 A at 380...400 V conforming to IEC 60947, 70 A at 660...690 V conforming to IEC 60947
Rated Operational Coltage Limits Power Circuit: 690 V AC 50/60 Hz
Safety Reliability Level B10d = 1369863 cycles contactor with nominal load conforming to EN/ISO 13849-1, B10d = 20000000 cycles contactor with mechanical load conforming to EN/ISO 13849-1
Signalling Circuit Frequency <= 400 Hz
Standards EN/IEC 60947-4-1, GB/T 14048.4, UL 60947-4-1, CSA C22.2 No 60947-4-1, JIS C8201-4-1
Width 45mm
Tightening Torque 0.8-1.3 N.m - on screw clamp terminals Philips No 2, 0.8-1.3 N.m - on screw clamp terminals flat Ø 6 mm
Utilisation Category AC-1
Rated Short-time Withstand Current 90 A 50 °C - 1 s for power circuit, 85 A 50 °C - 5 s for power circuit, 80 A 50 °C - 10 s for power circuit, 60 A 50 °C - 30 s for power circuit, 45 A 50 °C - 1 min for power circuit, 40 A 50 °C - 3 min for power circuit, 20 A 50 °C - >= 15 min for power circuit
Rated Operational Current 20 A (at <50 °C) at <= 440 V AC AC-1 for power circuit, 16 A (at <70 °C) at 690 V AC AC-1 for power circuit
Electrical Durability 0.18 Mcycles 20 A AC-1 at Ue <= 440 V
Weight 0.18 kg
WhatsApp Contact Button - Click to chat on WhatsApp