Brand : Schneider Electric

Type : Contactor

Collections

Description

Schneider Electric LC1K09008B7 TeSys K Contactor, 4 poles (2 NO + 2 NC), for non-inductive load control applications up to 20 A/690 V AC-1. It has a 24 V AC coil at 50/60 Hz, without built-in auxiliary contact and connection via screw terminals. For operating rates up to 600 cycles/hour and environments up to 50°C, it ensures reliability and durability in standard applications.

Very compact (45mm wide), DIN rail mounting or screw mounting. Multi-standard certification (IEC, UL, CSA, CCC, EAC), Green Premium compliant (RoHS/REACh).

Features
  • 20A TP AC1 Contactor AC1 24V AC Coil
  • Used to make or break an electrical connection
  • 4-pole contactor for connection by screw clamp terminals
Specifications
Brand Schneider Electric
Item Name Contactor
Model LC1K09008B7
Conventional Free Air Thermal Current 20 A (at 50 °C) for power circuit
Control Circuit Voltage 24 V AC 50/60 Hz
Rated Operational Voltage Limits Power Circuit: 690 V AC 50/60 Hz
Rated Insulation Voltage Power circuit: 600 V conforming to UL 508, power circuit: 690 V conforming to IEC 60947-4-1, power circuit: 600 V conforming to CSA C22.2 No 14
Rated Impulse Withstand Voltage 8 kV
Ambient Air Temperature For Storage -50-80 °C
Associated Fuse Rating 25 A gG at <= 440 V for power circuit, 25 A aM for power circuit
Average Impedance 3 mOhm - Ith 20 A 50 Hz for power circuit
Compatibility Code LC1K
Connections - Terminals Screw Clamp Terminals 1 cable(s) 1.5-4 mm²solid, screw clamp terminals 1 cable(s) 0.75-4 mm²flexible without cable end, screw clamp terminals 1 cable(s) 0.34-2.5 mm²flexible with cable end, screw clamp terminals 2 cable(s) 1.5-4 mm²solid, screw clamp terminals 2 cable(s) 0.75-4 mm²flexible without cable end, screw clamp terminals 2 cable(s) 0.34-1.5 mm²flexible with cable end
Contactor Application Resistive Load
Control Circuit Type AC at 50/60 Hz
Control Circuit Voltage Limits Operational: 0.8...1.15 Uc (at <50 °C), drop-out: 0.2...0.75 Uc (at <50 °C)
Depth 57mm
Electrical Durability 0.18 Mcycles 20 A AC-1 at Ue <= 440 V
Flame Retardance V1 conforming to UL 94, requirement 2 conforming to NF F 16-101, requirement 2 conforming to NF F 16-102
Heat Dissipation 1.3-1.3 W
Height 58 mm
Hold-in Power Consumption in VA 4.5-4.5 VA (at 20 °C)
Inrush Power in VA 30-30 VA (at 20 °C)
Insulation Resistance > 10 MOhm for Signalling Circuit
IP Degree Of Protection IP2X conforming to VDE 0106
Irms Rated Making Capacity 110 A AC for power circuit conforming to NF C 63-110, 110 A AC for power circuit conforming to IEC 60947
Maximum Operating Rate 3600 cyc/h 60 °C
Mechanical Durability 10 Mcycles
Mechanical Robustness Shocks contactor closed, on X axis: 10 Gn for 11 ms conforming to IEC 60068-2-27, shocks contactor closed, on Y axis: 15 Gn for 11 ms conforming to IEC 60068-2-27, shocks contactor closed, on Z axis: 15 Gn for 11 ms conforming to IEC 60068-2-27, shocks contactor opened, on X axis: 6 Gn for 11 ms conforming to IEC 60068-2-27, shocks contactor opened, on Y axis: 10 Gn for 11 ms conforming to IEC 60068-2-27, shocks contactor opened, on Z axis: 10 Gn for 11 ms conforming to IEC 60068-2-27, vibrations contactor closed: 4 Gn, 5...300 Hz conforming to IEC 60068-2-6, vibrations contactor opened: 2 Gn, 5...300 Hz conforming to IEC 60068-2-6
Mounting Support Rail, Plate
Operating Altitude 2000 m without derating
Operating Time 10...20 ms coil de-energisation and NO opening, 10...20 ms coil energisation and NO closing, 15...25 ms coil de-energisation and NC closing, 5...15 ms coil energisation and NC opening
Overvoltage Category III
Pole Contact Composition 2 NO + 2 NC
Poles Description 4P
Pollution Degree 3
Certifications CB Scheme, CCC, UL, CSA, EAC, CE, UKCA
Protective Treatment TC conforming to IEC 60068, TC conforming to DIN 50016
Range TeSys K
Rated Breaking Capacity 110 A at 415 V conforming to IEC 60947, 110 A at 440 V conforming to IEC 60947, 80 A at 500 V conforming to IEC 60947, 110 A at 220...230 V conforming to IEC 60947, 110 A at 380...400 V conforming to IEC 60947, 70 A at 660...690 V conforming to IEC 60947
Safety Reliability Level B10d = 1369863 cycles contactor with nominal load conforming to EN/ISO 13849-1, B10d = 20000000 cycles contactor with mechanical load conforming to EN/ISO 13849-1
Signalling Circuit Frequency <= 400 Hz
Standards EN/IEC 60947-4-1, GB/T 14048.4, UL 60947-4-1, CSA C22.2 No 60947-4-1, JIS C8201-4-1
Tightening Torque 0.8-1.3 N.m - on screw clamp terminals Philips No 2, 0.8-1.3 N.m - on screw clamp terminals flat Ø 6 mm, 0.8-1.3 N.m - on screw clamp terminals pozidriv No 2
Utilisation Category AC-1
Rated Operational Current 20 A (at <50 °C) at <= 440 V AC AC-1 for power circuit, 16 A (at <70 °C) at 690 V AC AC-1 for power circuit
Width 45 mm
Rated Short-time Withstand Current 90 A 50 °C - 1 s for power circuit, 85 A 50 °C - 5 s for power circuit, 80 A 50 °C - 10 s for power circuit, 60 A 50 °C - 30 s for power circuit, 45 A 50 °C - 1 min for power circuit, 40 A 50 °C - 3 min for power circuit, 20 A 50 °C - >= 15 min for power circuit
Weight 0.18 kg