Schneider Electric TeSys GC Modular Contactor 16 A 1 NO + 1 NC Coil 220-240V AC GC1611M5
(Price Includes VAT)
Order Now & Get it by 2 days
Sold by: Marketplace
Brand : Schneider Electric
Type : Modular Contactor
Description
Schneider Electric GC1611M5 TeSys GC Modular Contactor, 2 poles (1NO + 1NC), 16A/250V AC-7a (heating) and 5A/250V AC-7b (motor control), for domestic applications. Control voltage 220-240V AC 50Hz, status indication on the front. For use in modular, compact control panels (width 18 mm), attachable to 35 mm DIN rail, connection via screw terminals. Sold in lots of 12 units. Certified to multiple standards (IEC, EN, NF-USE, VDE, CEBEC, OVE), Green Premium compliant (RoHS/REACh).
Features
- Operating Position 30 Deg C /Vertical.
- Used to control electrical loads
Brand | Schneider Electric |
Item Name | Modular Contactor |
Model | GC1611M5 |
Color | White |
Conventional Free Air Thermal Current | 16 A (at 50 °C) for power circuit |
Control Circuit Voltage | 220...240 V AC 50 Hz |
Rated Operational Voltage | <= 250 V AC |
Rated Insulation Voltage | 500 V conforming to IEC 61095, 500 V conforming to VDE 0110 |
Rated Impulse Withstand Voltage | 4 kV |
Ambient Air Temperature For Operation | -5-50 °C |
Ambient Air Temperature For Storage | -40-70 °C |
Associated Fuse Rating | 16 A gL at <= 440 V for power circuit |
Average Impedance | 2.5 mOhm - Ith 16 A 50 Hz for power circuit |
Compatibility Code | Modular Standard Contactor |
Connections - Terminals | Control circuit: screw clamp terminals 1 cable(s) 2.5-2.5 mm²flexible without cable end, power circuit: screw clamp terminals 2 cable(s) 1.5-1.5 mm²flexible with cable end, power circuit: screw clamp terminals 1 cable(s) 6-6 mm²solid without cable end, power circuit: screw clamp terminals 2 cable(s) 4-4 mm²solid without cable end, control circuit: screw clamp terminals 2 cable(s) 2.5-2.5 mm²flexible without cable end, control circuit: screw clamp terminals 1 cable(s) 2.5-2.5 mm²flexible with cable end, control circuit: screw clamp terminals 2 cable(s) 1.5-1.5 mm²flexible with cable end, control circuit: screw clamp terminals 1 cable(s) 1.5-1.5 mm²solid without cable end, control circuit: screw clamp terminals 2 cable(s) 1.5-1.5 mm²solid without cable end, power circuit: screw clamp terminals 1 cable(s) 6-6 mm²flexible without cable end, power circuit: screw clamp terminals 2 cable(s) 4-4 mm²flexible without cable end, power circuit: screw clamp terminals 1 cable(s) 6-6 mm²flexible with cable end |
Contactor Application | Motor Control, Heating, Lighting |
Control Circuit Type | AC at 50 Hz |
Control Circuit Voltage Limits | Drop-out: 0.2...0.75 Uc at 50 Hz (at <50 °C), operational: 0.85...1.1 Uc at 50 Hz (at <50 °C) |
Control Type | Remote Control |
Depth | 62.5 mm |
Heat Dissipation | 1.3-1.3 W at 50/60 Hz |
Height | 81 mm |
Hold-in Power Consumption in VA | 3.8-3.8 VA 50 Hz (at 20 °C) |
Inrush Power in VA | 15-15 VA 50 Hz (at 20 °C) |
IP Degree Of Protection | IP40 conforming to VDE 0106 (in enclosure), IP20 conforming to VDE 0106 |
Irms Rated Making Capacity | 40 A at 400 V AC for power circuit conforming to IEC 61095 |
Maximum Operating Rate | 300 cyc/h 50 °C |
Mechanical Durability | 1000000 cycles |
Mechanical Robustness | Shocks contactor open: 10 Gn for 11 ms, shocks contactor closed: 15 Gn for 11 ms, vibrations contactor open: 2 Gn, 5...300 Hz, vibrations contactor closed: 3 Gn, 5...300 Hz |
Mounting Mode | Clip-On |
Mounting Support | DIN Rail |
Operating Altitude | <= 3000 m |
Operating Position | 30°/vertical |
Operating Time | 10...25 ms opening, 10...30 ms closing |
Pole Contact Composition | 1 NO + 1 NC |
Poles Description | 2P |
Power Dissipation Per Pole | 0.65 W |
Protective Treatment | TC |
Range | TeSys |
Rated Breaking Capacity | 40 A at 400 V for power circuit conforming to IEC 61095 |
Rated Operational Voltage Limits | <= 250 V AC |
Standards | IEC 60947-5, IEC 61095 |
Tightening Torque | Control circuit: 0.8 N.m - on screw clamp terminals, power circuit: 0.8 N.m - on screw clamp terminals |
Utilisation Category | AC-7B, AC-7A |
Total number of 18 mm modules | 1 |
Width | 17.5 mm |
Rated Short-time Withstand Current | 128 A 40 °C - 10 s for power circuit, 40 A 40 °C - 30 s for power circuit |
Electrical Durability | AC-7A: 100000 cycles, AC-7B: 100000 cycles |
Rated Operational Current | 16 A AC-7A, 5 A AC-7B |
Net Weight | 0.11 kg |