Schneider Electric TeSys D Contactor 4P(4 NO) AC-1 <= 440V 60A 240V AC 50/60Hz Coil LC1DT60AU7

AED 430.50

(Price Includes VAT)

Delivery truck icon

Order Now & Get it by 2 days

Shop logo

Sold by: Marketplace

Free delivery inside Dubai on all orders with no order limit. Pay in 4 interest-free installments for Dubai orders using Tabby.
Cash on delivery payment method icon
Cash on Delivery
7 Days Returnable icon
7 Days Returnable
15+ Years Of Trust icon
15+ Years Of Trust
15+ Branches icon
15+ Branches
Quantity

Brand : Schneider Electric

Type : Contactor

Collections

Description

Schneider Electric LC1DT60AU7 TeSys D Contactor is an electrical device used to switch an electrical circuit on or off. It is similar to a relay, but it is designed to handle higher current levels. The contactor has four poles. In electrical terms, a pole refers to a pair of contacts that open or close simultaneously. AC-1 refers to non-inductive or slightly inductive loads, such as resistance furnaces. It's essentially a category used to specify the type of load the contactor is designed to handle.

<= 440V 60A is the maximum voltage and current the contactor can handle. It's rated for up to 440 volts and can handle a maximum current of 60 amperes. 240V AC 50/60Hz Coil specifies the coil voltage and frequency. The contactor is designed to be activated by a 240-volt AC supply at either 50 or 60 Hertz.

In summary, Schneider Electric LC1DT60AU7 TeSys D Contactor is designed for handling non-inductive or slightly inductive loads up to 440 volts and 60 amperes. It has a 4-pole configuration and is activated by a 240-volt AC supply at 50 or 60 Hertz.

Features
  • 60A TP AC1 Contactor AC1 240V AC Coil
  • Used to make or break an electrical connection
  • 4-pole contactor for connection by screw clamp terminals
Specifications
Brand Schneider Electric
Item Name Contactor
Model LC1DT60AU7
Conventional Free Air Thermal Current 10 A (at 60 °C) for signalling circuit, 60 A (at 60 °C) for power circuit
Control Circuit Voltage 240 V AC 50/60 Hz
Rated Insulation Voltage Power Circuit: 600 V CSA certified, power circuit: 600 V UL certified, signalling circuit: 690 V conforming to IEC 60947-1, signalling circuit: 600 V CSA certified, signalling circuit: 600 V UL certified, power circuit: 690 V conforming to IEC 60947-4-1
Rated Impulse Withstand Voltage 6 kV conforming to IEC 60947
Associated Fuse Rating 10 A gG for signalling circuit conforming to IEC 60947-5-1, 80 A gG at <= 690 V coordination type 1 for power circuit, 80 A gG at <= 690 V coordination type 2 for power circuit
Auxiliary Contact Composition 1 NO + 1 NC
Auxiliary Contacts Type Type mechanically linked 1 NO + 1 NC conforming to IEC 60947-5-1, type mirror contact 1 NC conforming to IEC 60947-4-1
Average Impedance 1.6 mOhm - Ith 60 A 50 Hz for power circuit
Climatic Withstand Conforming to IACS E10 exposure to damp heat, conforming to IEC 60947-1 Annex Q category D exposure to damp heat
Coil Technology Without built-in suppressor module
Compatibility Code LC1D
Connections - Terminals Control Circuit: screw clamp terminals 2 1-2.5 mm² - cable stiffness: flexible with cable end, control circuit: screw clamp terminals 1 1-4 mm² - cable stiffness: flexible without cable end, control circuit: screw clamp terminals 2 1-4 mm² - cable stiffness: flexible without cable end, control circuit: screw clamp terminals 1 1-4 mm² - cable stiffness: flexible with cable end, control circuit: screw clamp terminals 1 1-4 mm² - cable stiffness: solid without cable end, control circuit: screw clamp terminals 2 1-4 mm² - cable stiffness: solid without cable end, power circuit: screw clamp terminal 1 1-35 mm² - cable stiffness: flexible without cable end, power circuit: screw clamp terminal 2 1-25 mm² - cable stiffness: flexible without cable end, power circuit: screw clamp terminal 1 1-35 mm² - cable stiffness: flexible with cable end, power circuit: screw clamp terminal 2 1-25 mm² - cable stiffness: flexible with cable end, power circuit: screw clamp terminal 1 1-35 mm² - cable stiffness: solid without cable end, power circuit: screw clamp terminal 2 1-25 mm² - cable stiffness: solid without cable end
Contact Compatibility M6
Contactor Application Motor Control, Resistive Load
Control Circuit Type AC at 50/60 Hz
Control Circuit Voltage Limits 0.3...0.6 Uc (-40-70 °C):drop-out AC 50/60 Hz, 0.8...1.1 Uc (-40-60 °C):operational AC 50 Hz, 0.85...1.1 Uc (-40-60 °C):operational AC 60 Hz, 1...1.1 Uc (60-70 °C):operational AC 50/60 Hz
Depth 120 mm
Electrical Durability 1.4 Mcycles 60 A AC-1 at Ue <= 440 V
Fire Resistance 850 °C Conforming to IEC 60695-2-1
Flame Retardance V1 conforming to UL 94
Heat Dissipation 4-5 W at 50/60 Hz
Height 122 mm
Hold-in Power Consumption in VA 13-13 VA 60 Hz cos phi 0.3 (at 20 °C), 15-15 VA 50 Hz cos phi 0.3 (at 20 °C)
Inrush Power in VA 140-140 VA 60 Hz cos phi 0.75 (at 20 °C), 160-160 VA 50 Hz cos phi 0.75 (at 20 °C)
Insulation Resistance > 10 MOhm for Signalling Circuit
IP Degree Of Protection IP20 Front Face Conforming to IEC 60529
Irms Rated Making Capacity 140 A AC for signalling circuit conforming to IEC 60947-5-1, 250 A DC for signalling circuit conforming to IEC 60947-5-1, 450 A at 440 V for power circuit conforming to IEC 60947
Maximum Operating Rate 3600 cyc/h 60 °C
Mechanical Durability 6 Mcycles
Mechanical Robustness vibrations contactor open (2 Gn, 5...300 Hz) , vibrations contactor closed (4 Gn, 5...300 Hz) , shocks contactor closed (15 Gn for 11 ms) , shocks contactor open (8 Gn for 11 ms)
Minimum Switching Current 5 mA for signalling circuit
Minimum Switching Voltage 17 V for signalling circuit
Mounting Support Rail, Plate
Non-overlap Time 1.5 ms on de-energisation between NC and NO contact, 1.5 ms on energisation between NC and NO contact
Operating Altitude 0...3000 m
Operating Time 4...19 ms opening, 12...26 ms closing
Overvoltage Category III
Permissible Ambient Air Temperature Around The Device -40-60 °C, 60-70 °C with derating
Pole Contact Composition 4 NO
Poles Description 4P
Pollution Degree 3
Power Dissipation Per Pole 5.8 W AC-1
Certifications DNV, RINA, UL, BV, LROS (Lloyds register of shipping), CCC, CSA, GOST, GL
Protective Cover With
Protective Treatment TH Conforming to IEC 60068-2-30
Range TeSys, TeSys Deca
Rated Breaking Capacity 800 A at 440 V for power circuit conforming to IEC 60947
Rated Operational Voltage Limits Power Circuit: <= 690 V AC 25...400 Hz, power circuit: <= 300 V DC
Safety Reliability Level B10d = 1369863 cycles contactor with nominal load conforming to EN/ISO 13849-1, B10d = 20000000 cycles contactor with mechanical load conforming to EN/ISO 13849-1
Signalling Circuit Frequency 25...400 Hz
Standards CSA C22.2 No 14, EN 60947-4-1, EN 60947-5-1, IEC 60947-4-1, IEC 60947-5-1, UL 508, IEC 60335-1
Tightening Torque Control Circuit: 1.7 N.m - on EverLink BTR screw connectors - with screwdriver flat Ø 6 mm, control circuit: 1.7 N.m - on EverLink BTR screw connectors - with screwdriver Philips No 2, power circuit: 8 N.m - on EverLink BTR screw connectors - cable 25-35 mm² hexagonal screw head 4 mm, power circuit: 5 N.m - on EverLink BTR screw connectors - cable 1-25 mm² hexagonal screw head 4 mm, control circuit: 1.7 N.m - on EverLink BTR screw connectors - with screwdriver pozidriv No 2, power circuit: 2.5 N.m - on EverLink BTR screw connectors - with screwdriver pozidriv No 2
Utilisation Category AC-1
Rated Operational Current 60 A (at <60 °C) at <= 440 V AC AC-1 for power circuit
Width 70 mm
Rated Short-time Withstand Current 320 A 40 °C - 10 s for power circuit, 720 A 40 °C - 1 s for power circuit, 72 A 40 °C - 10 min for power circuit, 165 A 40 °C - 1 min for power circuit, 100 A - 1 s for signalling circuit, 120 A - 500 ms for signalling circuit, 140 A - 100 ms for signalling circuit
Weight 1.09 kg