Schneider Electric TeSys D Contactor 3P(3 NO) AC-3 <= 440V 80A 48V AC 50/60Hz Coil LC1D80E7

AED 369.00

(Price Includes VAT)

Notice: Pricing Updates

Due to current global supply and market conditions, product prices may occasionally change. If there is any change in the price of items in your order, our customer support team will reach out to you for confirmation before proceeding further. We sincerely appreciate your understanding and thank you for your continued support.

Delivery truck icon

Order Now & Get it by 2 - 3 Working Days

Shop logo

Sold by: Marketplace

Free delivery inside Dubai on all orders with no order limit. Pay in 4 interest-free installments for Dubai orders using Tabby.
Cash on delivery payment method icon
Cash on Delivery
7 Days Returnable icon
7 Days Returnable
15+ Years Of Trust icon
15+ Years Of Trust
15+ Branches icon
15+ Branches
Quantity

Eid al-Fitr Holiday Notice: Our shop, customer support, and delivery services will be temporarily unavailable during the holiday and will resume on Monday. You may continue to place orders online, and all orders will be processed once we reopen. We sincerely appreciate your understanding and support.

Brand : Schneider Electric

Type : Contactor

Collections

Description

Schneider Electric LC1D80E7 TeSys D Contactor is an electrical device used to control an electric motor or other high-power electrical loads. It is typically used in applications where a large current needs to be controlled by a smaller control circuit. It is a three-pole contactor. It means that it has three sets of contacts that can be used to control three separate electrical circuits.

AC-3 is used for starting squirrel-cage motors and switching off running motors. <= 440V 80A is the maximum voltage and current rating for the contactor. It can handle voltages up to 440 volts and currents up to 80 amperes. 48V AC 50/60 Hz Coil is the coil voltage and frequency required to energize the contactor. In this case, the contactor's coil operates on 48 volts AC with a frequency range of either 50 or 60 Hertz.

So, in summary, Schneider Electric LC1D80E7 TeSys D Contactor is designed for handling up to 440 volts and 80 amperes in AC-3 applications, and it requires a 48-volt AC supply at either 50 or 60 Hertz to operate its coil.

Features
  • 80A TP AC3 Contactor AC3 48V AC Coil
  • Control the flow of electric current in a circuit
  • 3-pole contactor for connection by screw clamp terminals
Specifications
Brand Schneider Electric
Item Name Contactor
Model LC1D80E7
Conventional Free Air Thermal Current 10 A (at 60 °C) for signalling circuit, 125 A (at 60 °C) for power circuit
Control Circuit Voltage 48 V AC 50/60 Hz
Rated Operational Voltage Power Circuit: <= 690 V AC 25...400 Hz, power circuit: <= 300 V DC
Rated Insulation Voltage power circuit: 600 V CSA certified, power circuit: 600 V UL certified, power circuit: 1000 V conforming to IEC 60947-4-1, signalling circuit: 690 V conforming to IEC 60947-1, signalling circuit: 600 V CSA certified, signalling circuit: 600 V UL certified
Rated Impulse Withstand Voltage 8 kV conforming to IEC 60947
Associated Fuse Rating 10 A gG for signalling circuit conforming to IEC 60947-5-1, 200 A gG at <= 690 V coordination type 1 for power circuit, 160 A gG at <= 690 V coordination type 2 for power circuit
Auxiliary Contact Composition 1 NO + 1 NC
Auxiliary Contacts Type Type mechanically linked 1 NO + 1 NC conforming to IEC 60947-5-1, type mirror contact 1 NC conforming to IEC 60947-4-1
Average Impedance 0.8 mOhm - Ith 125 A 50 Hz for power circuit
Climatic Withstand Conforming to IACS E10 exposure to damp heat, conforming to IEC 60947-1 Annex Q category D exposure to damp heat
Coil Technology Without built-in suppressor module
Compatibility Code LC1D
Connections - Terminals control circuit: screw clamp terminals 2 1-2.5 mm² - cable stiffness: flexible with cable end, control circuit: screw clamp terminals 1 1-2.5 mm² - cable stiffness: flexible with cable end, control circuit: screw clamp terminals 1 1-4 mm² - cable stiffness: flexible without cable end, control circuit: screw clamp terminals 2 1-4 mm² - cable stiffness: flexible without cable end, control circuit: screw clamp terminals 1 1-4 mm² - cable stiffness: solid without cable end, control circuit: screw clamp terminals 2 1-4 mm² - cable stiffness: solid without cable end, power circuit: connector 1 4-50 mm² - cable stiffness: flexible without cable end, power circuit: connector 2 4-25 mm² - cable stiffness: flexible without cable end, power circuit: connector 1 4-50 mm² - cable stiffness: flexible with cable end, power circuit: connector 2 4-16 mm² - cable stiffness: flexible with cable end, power circuit: connector 1 4-50 mm² - cable stiffness: solid without cable end, power circuit: connector 2 4-25 mm² - cable stiffness: solid without cable end
Contact Compatibility M11
Contactor Application Motor Control, Resistive Load
Control Circuit Type AC at 50/60 Hz Standard
Control Circuit Voltage Limits 0.85...1.1 Uc (-40-55 °C):operational AC 60 Hz, 0.3...0.6 Uc (-40-70 °C):drop-out AC 50/60 Hz, 0.8...1.1 Uc (-40-55 °C):operational AC 50 Hz, 1...1.1 Uc (55-70 °C):operational AC 50/60 Hz
Depth 130mm
Electrical Durability 1.2 Mcycles 95 A AC-3, 1.3 Mcycles 125 A AC-1, 1.2 Mcycles 95 A AC-3e
Fire Resistance 850 °C conforming to IEC 60695-2-1
Flame Retardance V1 Conforming to UL 94
Heat Dissipation 6-10 W at 50/60 Hz
Height 127 mm
Hold-in Power Consumption in VA 26-26 VA 60 Hz cos phi 0.3 (at 20 °C), 26-26 VA 50 Hz cos phi 0.3 (at 20 °C)
Inrush Power in VA 245-245 VA 60 Hz cos phi 0.75 (at 20 °C), 245-245 VA 50 Hz cos phi 0.75 (at 20 °C)
Insulation Resistance > 10 MOhm for Signalling Circuit
IP Degree Of Protection IP20 Front Face Conforming to IEC 60529
Irms Rated Making Capacity 140 A AC for signalling circuit conforming to IEC 60947-5-1, 250 A DC for signalling circuit conforming to IEC 60947-5-1, 1100 A at 440 V for power circuit conforming to IEC 60947
Maximum Operating Rate 3600 cyc/h 60 °C
Mechanical Durability 4 Mcycles
Mechanical Robustness vibrations contactor open (2 Gn, 5...300 Hz) , shocks contactor open (8 Gn for 11 ms) , vibrations contactor closed (3 Gn, 5...300 Hz) , shocks contactor closed (10 Gn for 11 ms)
Minimum Switching Current 5 mA for signalling circuit
Minimum Switching Voltage 17 V for signalling circuit
Motor Power hp 7.5 hp at 120 V AC 60 Hz for 1 phase motors, 15 hp at 230/240 V AC 60 Hz for 1 phase motors, 30 hp at 200/208 V AC 60 Hz for 3 phases motors, 30 hp at 230/240 V AC 60 Hz for 3 phases motors, 60 hp at 460/480 V AC 60 Hz for 3 phases motors, 60 hp at 575/600 V AC 60 Hz for 3 phases motors
Motor Power kW 22 kW at 220...230 V AC 50/60 Hz (AC-3), 37 kW at 380...400 V AC 50/60 Hz (AC-3), 45 kW at 415...440 V AC 50/60 Hz (AC-3), 55 kW at 500 V AC 50/60 Hz (AC-3), 45 kW at 660...690 V AC 50/60 Hz (AC-3), 15 kW at 400 V AC 50/60 Hz (AC-4), 22 kW at 220...230 V AC 50/60 Hz (AC-3e), 37 kW at 380...400 V AC 50/60 Hz (AC-3e), 45 kW at 415...440 V AC 50/60 Hz (AC-3e), 55 kW at 500 V AC 50/60 Hz (AC-3e), 45 kW at 660...690 V AC 50/60 Hz (AC-3e)
Mounting Support Rail, Plate
Non-overlap Time 1.5 ms on de-energisation between NC and NO contact, 1.5 ms on energisation between NC and NO contact
Operating Altitude 0...3000 m
Operating Time 20...35 ms closing, 6...20 ms opening
Overvoltage Category III
Permissible Ambient Air Temperature Around The Device -40-60 °C, 60-70 °C with derating
Pole Contact Composition 3 NO
Poles Description 3P
Pollution Degree 3
Power Dissipation Per Pole 5.1 W AC-3, 12.5 W AC-1, 5.1 W AC-3e
Certifications CSA, BV, UL, GOST, RINA, CCC, GL, LROS (Lloyds register of shipping), DNV
Protective Cover With
Protective Treatment TH conforming to IEC 60068-2-30
Range TeSys, TeSys Deca
Rated Breaking Capacity 1100 A at 440 V for power circuit conforming to IEC 60947
Rated Operational Voltage Limits power circuit: <= 690 V AC 25...400 Hz, power circuit: <= 300 V DC
Safety Reliability Level B10d = 1.3 Mcycles contactor with nominal load conforming to EN/ISO 13849-1, B10d = 20 Mcycles contactor with mechanical load conforming to EN/ISO 13849-1
Signalling Circuit Frequency 25...400 Hz
Standards CSA C22.2 No 14, EN 60947-4-1, EN 60947-5-1, IEC 60947-4-1, IEC 60947-5-1, UL 508
Tightening Torque control circuit: 1.2 N.m - on screw clamp terminals - with screwdriver flat Ø 6 mm, control circuit: 1.2 N.m - on screw clamp terminals - with screwdriver Philips No 2, power circuit: 12 N.m - on connector - with screwdriver flat Ø 6 to Ø 8 mm, power circuit: 12 N.m - on connector hexagonal screw head 4 mm, control circuit: 1.2 N.m - on screw clamp terminals - with screwdriver pozidriv No 2
Utilisation Category AC-3, AC-3e, AC-4, AC-1
Width 85 mm
Rated Short-time Withstand Current 640 A 40 °C - 10 s for power circuit, 990 A 40 °C - 1 s for power circuit, 135 A 40 °C - 10 min for power circuit, 320 A 40 °C - 1 min for power circuit, 100 A - 1 s for signalling circuit, 120 A - 500 ms for signalling circuit, 140 A - 100 ms for signalling circuit
Weight 1.59 kg