Schneider Electric TeSys D Contactor 3P(3 NO) AC-3 <= 440V 65A 48V AC 50/60Hz Coil LC1D65AE7

AED 296.00

(Price Includes VAT)

Delivery truck icon

Order Now & Get it by 2 days

Shop logo

Sold by: Marketplace

Free delivery inside Dubai on all orders with no order limit. Pay in 4 interest-free installments for Dubai orders using Tabby.
Cash on delivery payment method icon
Cash on Delivery
7 Days Returnable icon
7 Days Returnable
15+ Years Of Trust icon
15+ Years Of Trust
15+ Branches icon
15+ Branches
Quantity

Brand : Schneider Electric

Type : Contactor

Collections

Description

Schneider Electric LC1D65AE7 TeSys D Contactor is an electrically controlled switch used for switching a power circuit. It's typically used in applications where a large amount of current needs to be controlled, such as in motors or heating elements. It is a three-pole contactor. This means it can control three phases of electrical power.

AC-3 is typically used for starting and stopping squirrel cage motors. It is rated to handle a maximum voltage of 440 volts and a maximum current of 65 amperes. 48V AC 50/60 Hz Coil is the voltage and frequency at which the contactor's coil operates. In this case, the coil operates at 48 volts AC, and it's designed to work with power sources that have a frequency of either 50 Hz or 60 Hz.

Features
  • 65A TP AC3 Contactor AC3 48V AC Coil
  • Control the flow of electric current in a circuit
  • 3-pole contactor for connection by screw clamp terminals
Specifications
Brand Schneider Electric
Item Name Contactor
Model LC1D65AE7
Conventional Free Air Thermal Current 10 A (at 60 °C) for signalling circuit, 80 A (at 60 °C) for power circuit
Control Circuit Voltage 48 V AC 50/60 Hz
Rated Operational Voltage Limits Power Circuit: <= 690 V AC 25...400 Hz, power circuit: <= 300 V DC
Rated Insulation Voltage power circuit: 600 V CSA certified, power circuit: 600 V UL certified, signalling circuit: 690 V conforming to IEC 60947-1, signalling circuit: 600 V CSA certified, signalling circuit: 600 V UL certified, power circuit: 690 V conforming to IEC 60947-4-1
Rated Impulse Withstand Voltage 6 kV conforming to IEC 60947
Associated Fuse Rating 10 A gG for signalling circuit conforming to IEC 60947-5-1, 125 A gG at <= 690 V coordination type 1 for power circuit, 125 A gG at <= 690 V coordination type 2 for power circuit
Auxiliary Contact Composition 1 NO + 1 NC
Auxiliary Contacts Type Type mechanically linked 1 NO + 1 NC conforming to IEC 60947-5-1, type mirror contact 1 NC conforming to IEC 60947-4-1
Average Impedance 1.5 mOhm - Ith 80 A 50 Hz for power circuit
Climatic Withstand Conforming to IACS E10 exposure to damp heat, conforming to IEC 60947-1 Annex Q category D exposure to damp heat
Coil Technology Without built-in suppressor module
Compatibility Code LC1D
Connections - Terminals Control Circuit: screw clamp terminals 2 1-2.5 mm² - cable stiffness: flexible with cable end, control circuit: screw clamp terminals 1 1-4 mm² - cable stiffness: flexible without cable end, control circuit: screw clamp terminals 2 1-4 mm² - cable stiffness: flexible without cable end, control circuit: screw clamp terminals 1 1-4 mm² - cable stiffness: flexible with cable end, control circuit: screw clamp terminals 1 1-4 mm² - cable stiffness: solid without cable end, control circuit: screw clamp terminals 2 1-4 mm² - cable stiffness: solid without cable end, power circuit: screw connection 1 1-35 mm² - cable stiffness: flexible without cable end, power circuit: screw connection 2 1-25 mm² - cable stiffness: flexible without cable end, power circuit: screw connection 1 1-35 mm² - cable stiffness: flexible with cable end, power circuit: screw connection 2 1-25 mm² - cable stiffness: flexible with cable end, power circuit: screw connection 1 1-35 mm² - cable stiffness: solid without cable end, power circuit: screw connection 2 1-25 mm² - cable stiffness: solid without cable end
Contact Compatibility M2
Contactor Application Motor Control, Resistive Load
Control Circuit Type AC at 50/60 Hz Standard
Control Circuit Voltage Limits 0.3...0.6 Uc (-40-70 °C):drop-out AC 50/60 Hz, 0.8...1.1 Uc (-40-60 °C):operational AC 50 Hz, 0.85...1.1 Uc (-40-60 °C):operational AC 60 Hz, 1...1.1 Uc (60-70 °C):operational AC 50/60 Hz
Depth 120mm
Electrical Durability 1.4 Mcycles 60 A AC-1 at Ue <= 440 V, 1.5 Mcycles 40 A AC-3 at Ue <= 440 V, 1.5 Mcycles 40 A AC-3e at Ue <= 440 V
Fire Resistance 850 °C conforming to IEC 60695-2-1
Flame Retardance V1 Conforming to UL 94
Heat Dissipation 4-5 W at 50/60 Hz
Height 122 mm
Hold-in Power Consumption in VA 13-13 VA 60 Hz cos phi 0.3 (at 20 °C), 15-15 VA 50 Hz cos phi 0.3 (at 20 °C)
Inrush Power in VA 140-140 VA 60 Hz cos phi 0.75 (at 20 °C), 160-160 VA 50 Hz cos phi 0.75 (at 20 °C)
Insulation Resistance > 10 MOhm for Signalling Circuit
IP Degree Of Protection IP20 Front Face Conforming to IEC 60529
Irms Rated Making Capacity 140 A AC for signalling circuit conforming to IEC 60947-5-1, 250 A DC for signalling circuit conforming to IEC 60947-5-1, 1000 A at 440 V for power circuit conforming to IEC 60947
Maximum Operating Rate 3600 cyc/h 60 °C
Mechanical Durability 6 Mcycles
Mechanical Robustness vibrations contactor open (2 Gn, 5...300 Hz) , vibrations contactor closed (4 Gn, 5...300 Hz) , shocks contactor closed (15 Gn for 11 ms) , shocks contactor open (10 Gn for 11 ms)
Minimum Switching Current 5 mA for signalling circuit
Minimum Switching Voltage 17 V for signalling circuit
Motor Power hp 40 hp at 460/480 V AC 50/60 Hz for 3 phases motors, 5 hp at 115 V AC 50/60 Hz for 1 phase motors, 10 hp at 230/240 V AC 50/60 Hz for 1 phase motors, 20 hp at 200/208 V AC 50/60 Hz for 3 phases motors, 20 hp at 230/240 V AC 50/60 Hz for 3 phases motors, 50 hp at 575/600 V AC 50/60 Hz for 3 phases motors
Motor Power kW 11 kW at 400 V AC 50/60 Hz (AC-4), 18.5 kW at 220...230 V AC 50/60 Hz (AC-3), 30 kW at 380...400 V AC 50/60 Hz (AC-3), 37 kW at 500 V AC 50/60 Hz (AC-3), 37 kW at 660...690 V AC 50/60 Hz (AC-3), 18.5 kW at 220...230 V AC 50/60 Hz (AC-3e), 30 kW at 380...400 V AC 50/60 Hz (AC-3e), 37 kW at 500 V AC 50/60 Hz (AC-3e), 37 kW at 660...690 V AC 50/60 Hz (AC-3e)
Mounting Support Rail, Plate
Non-overlap Time 1.5 ms on de-energisation between NC and NO contact, 1.5 ms on energisation between NC and NO contact
Operating Altitude 0...3000 m
Operating Time 4...19 ms opening, 12...26 ms closing
Overvoltage Category III
Permissible Ambient Air Temperature Around The Device -40-60 °C, 60-70 °C with derating
Pole Contact Composition 3 NO
Poles Description 3P
Pollution Degree 3
Power Dissipation Per Pole 9.6 W AC-1, 6.3 W AC-3, 6.3 W AC-3e
Certifications CSA, CCC, GOST, UL
Protective Cover With
Protective Treatment TH conforming to IEC 60068-2-30
Range TeSys, TeSys Deca
Rated Breaking Capacity 1000 A at 440 V for power circuit conforming to IEC 60947
Rated Operational Voltage Limits power circuit: <= 690 V AC 25...400 Hz, power circuit: <= 300 V DC
Safety Reliability Level B10d = 1.3 Mcycles contactor with nominal load conforming to EN/ISO 13849-1, B10d = 20 Mcycles contactor with mechanical load conforming to EN/ISO 13849-1
Signalling Circuit Frequency 25...400 Hz
Standards CSA C22.2 No 14, EN 60947-4-1, EN 60947-5-1, IEC 60947-4-1, IEC 60947-5-1, UL 508, IEC 60335-1
Tightening Torque control circuit: 1.7 N.m - on EverLink BTR screw connectors - with screwdriver flat Ø 6 mm, control circuit: 1.7 N.m - on EverLink BTR screw connectors - with screwdriver Philips No 2, power circuit: 8 N.m - on EverLink BTR screw connectors - cable 25-35 mm² hexagonal screw head 4 mm, power circuit: 5 N.m - on EverLink BTR screw connectors - cable 1-25 mm² hexagonal screw head 4 mm, control circuit: 1.7 N.m - on EverLink BTR screw connectors - with screwdriver pozidriv No 2, power circuit: 2.5 N.m - on EverLink BTR screw connectors - with screwdriver pozidriv No 2
Utilisation Category AC-4, AC-1, AC-3, AC-3e
Width 55 mm
Rated Short-time Withstand Current 520 A 40 °C - 10 s for power circuit, 900 A 40 °C - 1 s for power circuit, 110 A 40 °C - 10 min for power circuit, 260 A 40 °C - 1 min for power circuit, 100 A - 1 s for signalling circuit, 120 A - 500 ms for signalling circuit, 140 A - 100 ms for signalling circuit
Rated Operational Current 80 A (at <60 °C) at <= 440 V AC AC-1 for power circuit, 65 A (at <60 °C) at <= 440 V AC AC-3 for power circuit, 65 A (at <60 °C) at <= 440 V AC AC-3e for power circuit
Electrical Durability 1.4 Mcycles 80 A AC-1 at Ue <= 440 V, 1.45 Mcycles 65 A AC-3 at Ue <= 440 V, 1.45 Mcycles 65 A AC-3e at Ue <= 440 V
Weight 0.86 kg