Schneider Electric TeSys D contactor 3P(3 NO) AC-3 <= 440V 40A 48V AC 50/60Hz Coil LC1D40AE7

Schneider Electric TeSys D contactor 3P(3 NO) AC-3 <= 440V 40A 48V AC 50/60Hz Coil LC1D40AE7

Regular price AED 305.00
(Price Inclusive of VAT)
Marketplace
Delivery by 2-3 Days
Cash On Delivery
7 Days Returnable
15+ Years Of Trust
15+ Branches
Quantity
Note: This product is a marketplace product, it's availability and delivery time will be inform you, when you place an order or you can check by contacting us through whatsapp or by call.
Brand:Schneider Electric
Collections:Electricals
Type:Contactor
Description

    Schneider Electric LC1D40AE7 TeSys D Contactor is an electrically-controlled switch used for switching an electrical power circuit. It is typically used in applications where a device or load needs to be controlled remotely or automatically. The contactor has three poles, which means it can control a three-phase circuit. AC-3 contactors are primarily used for starting and stopping squirrel cage motors during normal operation.

    <= 440V is the contactor rated to handle voltages up to 440 volts. This is a common rating for industrial applications. 40A is the maximum current the contactor can handle. 48V AC 50/60 Hz Coil is the voltage and frequency of the coil used to control the contactor. It is designed to be controlled by a 48-volt AC source that operates at either 50 or 60 Hertz.

    Features
    • 40A TP AC3 Contactor AC3 48V AC Coil
    • Control the flow of electric current in a circuit
    • 3-pole contactor for connection by screw clamp terminals
Specifications

    Brand : Schneider Electric

    Item Name : Contactor

    Model : LC1D40AE7

    Conventional Free Air Thermal Current : 10 A (at 60 °C) for signalling circuit, 60 A (at 60 °C) for power circuit

    Control Circuit Voltage : 48 V AC 50/60 Hz

    Rated Operational Voltage Limits : Power Circuit: <= 690 V AC 25...400 Hz, power circuit: <= 300 V DC

    Rated Insulation Voltage : power circuit: 600 V CSA certified, power circuit: 600 V UL certified, signalling circuit: 690 V conforming to IEC 60947-1, signalling circuit: 600 V CSA certified, signalling circuit: 600 V UL certified, power circuit: 690 V conforming to IEC 60947-4-1

    Rated Impulse Withstand Voltage : 8 kV conforming to IEC 60947

    Associated Fuse Rating : 10 A gG for signalling circuit conforming to IEC 60947-5-1, 80 A gG at <= 690 V coordination type 1 for power circuit, 80 A gG at <= 690 V coordination type 2 for power circuit

    Auxiliary Contact Composition : 1 NO + 1 NC

    Auxiliary Contacts Type : Type mechanically linked 1 NO + 1 NC conforming to IEC 60947-5-1, type mirror contact 1 NC conforming to IEC 60947-4-1

    Average Impedance : 1.5 mOhm - Ith 60 A 50 Hz for power circuit

    Climatic Withstand : Conforming to IACS E10 exposure to damp heat, conforming to IEC 60947-1 Annex Q category D exposure to damp heat

    Coil Technology : Without built-in suppressor module

    Compatibility Code : LC1D

    Connections - Terminals : control circuit: screw clamp terminals 2 1-2.5 mm² - cable stiffness: flexible with cable end, control circuit: screw clamp terminals 1 1-4 mm² - cable stiffness: flexible without cable end, control circuit: screw clamp terminals 2 1-4 mm² - cable stiffness: flexible without cable end, control circuit: screw clamp terminals 1 1-4 mm² - cable stiffness: flexible with cable end, control circuit: screw clamp terminals 1 1-4 mm² - cable stiffness: solid without cable end, control circuit: screw clamp terminals 2 1-4 mm² - cable stiffness: solid without cable end, power circuit: screw connection 1 1-35 mm² - cable stiffness: flexible without cable end, power circuit: screw connection 2 1-25 mm² - cable stiffness: flexible without cable end, power circuit: screw connection 1 1-35 mm² - cable stiffness: flexible with cable end, power circuit: screw connection 2 1-25 mm² - cable stiffness: flexible with cable end, power circuit: screw connection 1 1-35 mm² - cable stiffness: solid without cable end, power circuit: screw connection 2 1-25 mm² - cable stiffness: solid without cable end

    Contact Compatibility : M2

    Contactor Application : Motor Control, Resistive Load

    Control Circuit Type : AC at 50/60 Hz Standard

    Control Circuit Voltage Limits : 0.3...0.6 Uc (-40-70 °C):drop-out AC 50/60 Hz, 0.8...1.1 Uc (-40-60 °C):operational AC 50 Hz, 0.85...1.1 Uc (-40-60 °C):operational AC 60 Hz, 1...1.1 Uc (60-70 °C):operational AC 50/60 Hz

    Depth : 120mm

    Electrical Durability : 1.4 Mcycles 60 A AC-1 at Ue <= 440 V, 1.5 Mcycles 40 A AC-3 at Ue <= 440 V, 1.5 Mcycles 40 A AC-3e at Ue <= 440 V

    Fire Resistance : 850 °C conforming to IEC 60695-2-1

    Flame Retardance : V1 Conforming to UL 94

    Heat Dissipation : 4-5 W at 50/60 Hz

    Height : 122 mm

    Hold-in Power Consumption in VA : 13-13 VA 60 Hz cos phi 0.3 (at 20 °C), 15-15 VA 50 Hz cos phi 0.3 (at 20 °C)

    Inrush Power in VA : 140-140 VA 60 Hz cos phi 0.75 (at 20 °C), 160-160 VA 50 Hz cos phi 0.75 (at 20 °C)

    Insulation Resistance : > 10 MOhm for Signalling Circuit

    IP Degree Of Protection : IP20 Front Face Conforming to IEC 60529

    Irms Rated Making Capacity : 140 A AC for signalling circuit conforming to IEC 60947-5-1, 250 A DC for signalling circuit conforming to IEC 60947-5-1, 800 A at 440 V for power circuit conforming to IEC 60947

    Maximum Operating Rate : 3600 cyc/h 60 °C

    Mechanical Durability : 6 Mcycles

    Mechanical Robustness : vibrations contactor open (2 Gn, 5...300 Hz) , shocks contactor open (8 Gn for 11 ms) , vibrations contactor closed (3 Gn, 5...300 Hz) , shocks contactor closed (10 Gn for 11 ms)

    Minimum Switching Current : 5 mA for signalling circuit

    Minimum Switching Voltage : 17 V for signalling circuit

    Motor Power hp : 5 hp at 230/240 V AC 50/60 Hz for 1 phase motors, 10 hp at 230/240 V AC 50/60 Hz for 3 phases motors, 30 hp at 575/600 V AC 50/60 Hz for 3 phases motors, 10 hp at 200/208 V AC 50/60 Hz for 3 phases motors, 3 hp at 115 V AC 50/60 Hz for 1 phase motors, 30 hp at 460/480 V AC 50/60 Hz for 3 phases motors

    Motor Power kW : 18.5 kW at 380...400 V AC 50/60 Hz (AC-3), 11 kW at 220...230 V AC 50/60 Hz (AC-3), 22 kW at 415...440 V AC 50/60 Hz (AC-3), 22 kW at 500 V AC 50/60 Hz (AC-3), 30 kW at 660...690 V AC 50/60 Hz (AC-3), 9 kW at 400 V AC 50/60 Hz (AC-4), 18.5 kW at 380...400 V AC 50/60 Hz (AC-3e), 11 kW at 220...230 V AC 50/60 Hz (AC-3e), 22 kW at 415...440 V AC 50/60 Hz (AC-3e), 22 kW at 500 V AC 50/60 Hz (AC-3e), 30 kW at 660...690 V AC 50/60 Hz (AC-3e)

    Mounting Support : Rail, Plate

    Non-overlap Time : 1.5 ms on de-energisation between NC and NO contact, 1.5 ms on energisation between NC and NO contact

    Operating Altitude : 0...3000 m

    Operating Time : 4...19 ms opening, 12...26 ms closing

    Overvoltage Category : III

    Permissible Ambient Air Temperature Around The Device : -40-60 °C, 60-70 °C with derating

    Pole Contact Composition : 3 NO

    Poles Description : 3P

    Pollution Degree : 3

    Power Dissipation Per Pole : 2.4 W AC-3, 5.4 W AC-1, 2.4 W AC-3e

    Certifications : GOST, CSA, UL, CCC

    Protective Cover : With

    Protective Treatment : TH conforming to IEC 60068-2-30

    Range : TeSys, TeSys Deca

    Rated Breaking Capacity : 800 A at 440 V for power circuit conforming to IEC 60947

    Rated Operational Voltage Limits : power circuit: <= 690 V AC 25...400 Hz, power circuit: <= 300 V DC

    Safety Reliability Level : B10d = 1.3 Mcycles contactor with nominal load conforming to EN/ISO 13849-1, B10d = 20 Mcycles contactor with mechanical load conforming to EN/ISO 13849-1

    Signalling Circuit Frequency : 25...400 Hz

    Standards : CSA C22.2 No 14, EN 60947-4-1, EN 60947-5-1, IEC 60947-4-1, IEC 60947-5-1, UL 508, IEC 60335-1

    Tightening Torque : control circuit: control circuit: 1.7 N.m - on screw clamp terminals - with screwdriver flat Ø 6 mm, control circuit: 1.7 N.m - on screw clamp terminals - with screwdriver Philips No 2, power circuit: 8 N.m - on EverLink BTR screw connectors - cable 25-35 mm² hexagonal screw head 4 mm, power circuit: 5 N.m - on EverLink BTR screw connectors - cable 1-25 mm² hexagonal screw head 4 mm, control circuit: 1.7 N.m - on screw clamp terminals - with screwdriver pozidriv No 2, power circuit: 2.5 N.m - on screw clamp terminals - with screwdriver pozidriv No 2

    Utilisation Category : AC-4, AC-1, AC-3, AC-3e

    Width : 55 mm

    Rated Short-time Withstand Current : 320 A 40 °C - 10 s for power circuit, 720 A 40 °C - 1 s for power circuit, 72 A 40 °C - 10 min for power circuit, 165 A 40 °C - 1 min for power circuit, 100 A - 1 s for signalling circuit, 120 A - 500 ms for signalling circuit, 140 A - 100 ms for signalling circuit

    Rated Operational Current : 60 A (at <60 °C) at <= 440 V AC AC-1 for power circuit, 40 A (at <60 °C) at <= 440 V AC AC-3 for power circuit, 40 A (at <60 °C) at <= 440 V AC AC-3e for power circuit

    Weight : 1.59 kg

Popular Products