Schneider Electric TeSys D contactor 3P(3 NO) AC-3 <= 440V 150A 220V AC 50/60Hz Coil LC1D150M7 in Dubai, UAE

Schneider Electric TeSys D contactor 3P(3 NO) AC-3 <= 440V 150A 220V AC 50/60Hz Coil LC1D150M7

Regular price AED 676.00
(Price Inclusive of VAT)
Marketplace
Delivery by 2-3 Days
Cash On Delivery
7 Days Returnable
15+ Years Of Trust
15+ Branches
Quantity
Note: This product is a marketplace product, it's availability and delivery time will be inform you, when you place an order or you can check by contacting us through whatsapp or by call.
Brand:Schneider Electric
Collections:Electricals
Type:Contactor
Description

    Schneider Electric LC1D150M7 TeSys D Contactor is an electrical device used to control the flow of electricity in a circuit. It is commonly used in control circuits to start and stop motors, and for other applications where heavy-duty switching is required. The contactor is designed for three-phase systems. It means it can handle three separate conductors for power distribution. AC-3 is specifically for starting and stopping squirrel cage motors.

    The contactor is rated operational voltage (440V) and the maximum current it can handle under normal operating conditions (150A). This means the contactor is suitable for systems with a voltage of up to 440V and a current of up to 150A. 220V AC 50/60 Hz Coil is the control voltage for the contactor. The coil is what electromagnetically closes the contacts in the contactor. The coil operates on a 220V AC supply and is compatible with both 50Hz and 60Hz frequencies.

    So, in summary, Schneider Electric LC1D150M7 TeSys D Contactor is designed for heavy-duty use in three-phase systems with voltages up to 440V and currents up to 150A. It's controlled by a 220V AC coil that can operate on either 50Hz or 60Hz frequencies. This type of contactor is commonly used in industrial applications for controlling motors and other high-power equipment.

    Features
    • 150A TP AC3 Contactor AC3 220V AC Coil
    • Control the flow of electric current in a circuit
    • 3-pole contactor for connection by screw clamp terminals
Specifications

    Brand : Schneider Electric

    Item Name : Contactor

    Model : LC1D150M7

    Conventional Free Air Thermal Current : 200 A (at 60 °C) for power circuit

    Control Circuit Voltage : 220 V AC 50/60 Hz

    Rated Insulation Voltage : Power Circuit: 690 V conforming to IEC 60947-4-1, power circuit: 600 V CSA certified, power circuit: 600 V UL certified, signalling circuit: 690 V conforming to IEC 60947-1, signalling circuit: 600 V CSA certified, signalling circuit: 600 V UL certified

    Rated Impulse Withstand Voltage : 8 kV conforming to IEC 60947

    Associated Fuse Rating : 10 A gG for signalling circuit conforming to IEC 60947-5-1, 315 A gG at <= 690 V coordination type 1 for power circuit, 250 A gG at <= 690 V coordination type 2 for power circuit

    Auxiliary Contact Composition : 1 NO + 1 NC

    Auxiliary Contacts Type : Type mechanically linked 1 NO + 1 NC conforming to IEC 60947-5-1, type mirror contact 1 NC conforming to IEC 60947-4-1

    Average Impedance : 0.6 mOhm - Ith 200 A 50 Hz for power circuit

    Climatic Withstand : Conforming to IACS E10 exposure to damp heat, conforming to IEC 60947-1 Annex Q category D exposure to damp heat

    Coil Technology : built-in bidirectional peak limiting diode suppressor

    Compatibility Code : LC1D

    Connections - Terminals : control circuit: screw clamp terminals 2 1-2.5 mm² - cable stiffness: flexible with cable end, control circuit: screw clamp terminals 1 1-2.5 mm² - cable stiffness: flexible with cable end, control circuit: screw clamp terminals 1 1-2.5 mm² - cable stiffness: flexible without cable end, control circuit: screw clamp terminals 2 1-2.5 mm² - cable stiffness: flexible without cable end, control circuit: screw clamp terminals 1 1-2.5 mm² - cable stiffness: solid without cable end, control circuit: screw clamp terminals 2 1-2.5 mm² - cable stiffness: solid without cable end, power circuit: connector 1 10-120 mm² - cable stiffness: flexible without cable end, power circuit: connector 2 10-50 mm² - cable stiffness: flexible without cable end, power circuit: connector 1 10-120 mm² - cable stiffness: flexible with cable end, power circuit: connector 2 10-50 mm² - cable stiffness: flexible with cable end, power circuit: connector 1 10-120 mm² - cable stiffness: solid without cable end, power circuit: connector 2 10-50 mm² - cable stiffness: solid without cable end

    Contact Compatibility : M13

    Contactor Application : Motor Control, Resistive Load

    Control Circuit : Type AC at 50/60 Hz

    Control Circuit Voltage Limits : 0.3...0.5 Uc (-40-70 °C):drop-out AC 50/60 Hz, 0.8...1.15 Uc (-40-55 °C):operational AC 50/60 Hz, 1...1.15 Uc (55-70 °C):operational AC 50/60 Hz

    Depth : 136 mm

    Electrical Durability : 0.85 Mcycles 150 A AC-3 at Ue <= 440 V, 1 Mcycles 200 A AC-1 at Ue <= 440 V, 0.85 Mcycles 150 A AC-3e at Ue <= 440 V

    Fire Resistance : 850 °C Conforming to IEC 60695-2-1

    Flame Retardance : V1 Conforming to UL 94

    Heat Dissipation : 3-4.5 W at 50/60 Hz

    Height : 158 mm

    Hold-in Power Consumption in VA : 2-18 VA 60 Hz cos phi 0.9 (at 20 °C), 2-18 VA 50 Hz cos phi 0.9 (at 20 °C)

    Inrush Power in VA : 280-350 VA 60 Hz cos phi 0.9 (at 20 °C), 280-350 VA 50 Hz cos phi 0.9 (at 20 °C)

    Insulation Resistance : > 10 MOhm for Signalling Circuit

    IP Degree Of Protection : IP20 front face conforming to IEC 60529

    Irms Rated Making Capacity : 140 A AC for signalling circuit conforming to IEC 60947-5-1, 250 A DC for signalling circuit conforming to IEC 60947-5-1, 1660 A at 440 V for power circuit conforming to IEC 60947

    Maximum Operating Rate : 1200 cyc/h 60 °C

    Mechanical Durability : 8 Mcycles

    Mechanical Robustness : vibrations contactor open (2 Gn, 5...300 Hz) , vibrations contactor closed (4 Gn, 5...300 Hz) , shocks contactor closed (15 Gn for 11 ms) , shocks contactor open (6 Gn for 11 ms)

    Minimum Switching Current : 5 mA for signalling circuit

    Minimum Switching Voltage : 17 V for signalling circuit

    Motor Power hp : 40 hp at 200/208 V AC 50/60 Hz for 3 phases motors, 50 hp at 230/240 V AC 50/60 Hz for 3 phases motors, 100 hp at 460/480 V AC 50/60 Hz for 3 phases motors, 125 hp at 575/600 V AC 50/60 Hz for 3 phases motors

    Motor Power kW : 40 kW at 220...230 V AC 50/60 Hz (AC-3), 75 kW at 380...400 V AC 50/60 Hz (AC-3), 80 kW at 415...440 V AC 50/60 Hz (AC-3), 90 kW at 500 V AC 50/60 Hz (AC-3), 100 kW at 660...690 V AC 50/60 Hz (AC-3), 75 kW at 1000 V AC 50/60 Hz (AC-3), 22 kW at 400 V AC 50/60 Hz (AC-4), 40 kW at 220...230 V AC 50/60 Hz (AC-3e), 75 kW at 380...400 V AC 50/60 Hz (AC-3e), 80 kW at 415...440 V AC 50/60 Hz (AC-3e), 90 kW at 500 V AC 50/60 Hz (AC-3e), 100 kW at 660...690 V AC 50/60 Hz (AC-3e), 75 kW at 1000 V AC 50/60 Hz (AC-3e)

    Mounting Support : Rail, plate

    Non-overlap Time : 1.5 ms on de-energisation between NC and NO contact, 1.5 ms on energisation between NC and NO contact

    Operating Altitude : 0...3000 m

    Operating Time : 20...35 ms closing, 40...75 ms opening

    Overvoltage Category : III

    Permissible Ambient Air Temperature Around The Device : -40-60 °C, 60-70 °C with derating

    Pole Contact Composition : 3 NO

    Poles Description : 3P

    Pollution Degree : 3

    Power Dissipation Per Pole : 24 W AC-1, 13.5 W AC-3, 13.5 W AC-3e

    Certifications : CCC, LROS (Lloyds register of shipping), GL, GOST, RINA, CSA, BV, UL, DNV, UKCA, CE

    Protective Cover : With

    Protective Treatment : TH Conforming to IEC 60068-2-30

    Range : TeSys, TeSys Deca

    Rated Breaking Capacity : 1400 A at 440 V for power circuit conforming to IEC 60947

    Rated Operational Voltage Limits : power circuit: <= 1000 V AC 25...400 Hz, power circuit: <= 300 V DC

    Safety Reliability Level : B10d = 1369863 cycles contactor with nominal load conforming to EN/ISO 13849-1, B10d = 20000000 cycles contactor with mechanical load conforming to EN/ISO 13849-1

    Signalling Circuit Frequency : 25...400 Hz

    Standards : CSA C22.2 No 14, EN 60947-4-1, EN 60947-5-1, IEC 60947-4-1, IEC 60947-5-1, UL 508

    Tightening Torque : control circuit: 1.2 N.m - on screw clamp terminals - with screwdriver flat Ø 6 mm, control circuit: 1.2 N.m - on screw clamp terminals - with screwdriver Philips No 2, power circuit: 12 N.m - on connector hexagonal screw head 4 mm, control circuit: 1.2 N.m - on screw clamp terminals - with screwdriver pozidriv No 2

    Utilisation Category : AC-3, AC-1, AC-4, AC-3e

    Width : 55 mm

    Rated Short-time Withstand Current : 250 A 40 °C - 10 min for power circuit, 580 A 40 °C - 1 min for power circuit, 1200 A 40 °C - 10 s for power circuit, 1400 A 40 °C - 1 s for power circuit, 100 A - 1 s for signalling circuit, 120 A - 500 ms for signalling circuit, 140 A - 100 ms for signalling circuit

    Weight : 2.5 kg

Popular Products