Brand : Schneider Electric

Type : Analog Input/Output Module

Collections

Description

Schneider Electric TM3TI4 4 Analog Inputs Module And Temperature is part of the Modicon TM3 range, a range of I/O expansion modules for the Modicon M221, M241, M251, and M262. The analog input module provides 4 inputs with 16-bit and 15-bit+ signal resolution. It is an input module with a nominal supply voltage of 24V DC and a current consumption of 45mA/50mA at 5V DC via bus connector, and 35mA/40mA at 24V DC via external power supply. 

Schneider Electric TM3TI4 Modicon TM3 4 Analog Inputs Module And Temperature Inputs can control variable speed drives or any device equipped with a current or voltage input. There is isolation between input and power at 1500 V AC, input and internal logic at 500 V AC. It has a removable screw terminal for electrical connection with a 3.81 mm pitch for inputs and supplies. It has an IP20 certification and has CE certification. Complies with EN/IEC 61131-2 and EN/IEC 61010-2-201 standards. This module is compatible with Modicon M262, Modicon M241, Modicon M251, and Modicon M221 logic controllers.

Supports DIN rail type TH35-15, DIN rail type TH35-7.5 according to IEC 60715, and plate or panel mounting with mounting kit. Modicon TM3 expansion modules are designed with a simple interlocking mounting mechanism. When assembling Modicon TM3 modules with logic controllers, a bus expansion connector is used for data distribution and power supply. Increase your controller performance with the Modicon TM3 I/O system, designed specifically for Modicon M221, M241, and M251 logic controllers.

Features
  • Provides 4 inputs with 16-bit and 15-bit+ signal resolution.
  • It has a removable screw terminal for electrical connection with a 3.81 mm pitch for inputs and supplies.
  • IP20 protection 
Specifications
Brand Schneider Electric
Item Name Analog Input Module
Model TM3TI4
Resistance To Electrostatic Discharge 8 kV in air conforming to EN/IEC 61000-4-2, 4 kV on contact conforming to EN/IEC 61000-4-2
Rated Supply Voltage 24 V DC
Current Consumption 45 mA at 5 V DC via bus connector, 50 mA at 5 V DC via bus connector, 35 mA at 24 V DC via external supply, 40 mA at 24 V DC via external supply
Depth 70 mm
Height 90 mm
IP Degree Of Protection IP20
Marking CE
Mounting Support Top hat type TH35-15 rail conforming to IEC 60715, top hat type TH35-7.5 rail conforming to IEC 60715, plate or panel with fixing kit
Operating Altitude 0...2000 m
Pollution Degree 2
Range Of Product Modicon TM3
Relative Humidity 10-95 %, without condensation (in operation), 10-95 %, without condensation (in storage)
Shock Resistance 15 gn for 11 ms
Supply Voltage Limits 20.4-28.8 V
Width 23.6 mm
Immunity To Microbreaks 10 ms
Resistance To Electromagnetic Fields 10 V/m 80 MHz...1 GHz conforming to EN/IEC 61000-4-3, 3 V/m 1.4 GHz...2 GHz conforming to EN/IEC 61000-4-3, 1 V/m 2 GHz...3 GHz conforming to EN/IEC 61000-4-3
Surge Withstand 1 kV power supply common mode conforming to EN/IEC 61000-4-5, 0.5 kV power supply differential mode conforming to EN/IEC 61000-4-5, 1 kV input common mode conforming to EN/IEC 61000-4-5
Resistance To Fast Transients 1 kV (I/O) conforming to EN/IEC 61000-4-4
Electromagnetic Emission Radiated emissions - test level: 40 dBμV/m QP class A ( 10 m) at 30-230 MHz conforming to EN/IEC 55011, radiated emissions - test level: 47 dBμV/m QP class A ( 10 m) at 230-1000 MHz conforming to EN/IEC 55011
Temperature Drift +/- 0.01 %FS/°C
Analogue Input Resolution 16 bits, 15 bits + sign
Analogue Input Number 4
Analogue Input Type Current 4...20 mA, current 0...20 mA, voltage 0...10 V, voltage - 10...10 V, thermocouple - 200...1000 °C with thermocouple J, thermocouple - 200...1300 °C with thermocouple K, thermocouple 0...1760 °C with thermocouple R, thermocouple 0...1760 °C with thermocouple S, thermocouple 0...1820 °C with thermocouple B, thermocouple - 200...400 °C with thermocouple T, thermocouple - 200...1300 °C with thermocouple N, thermocouple - 200...800 °C with thermocouple E, thermocouple 0...2315 °C with thermocouple C, Ni 100/Ni 1000 temperature probe - 60...180 °C, Pt 100 temperature probe - 200...850 °C, Pt 1000 temperature probe - 200...600 °C
Repeat Accuracy +/-0.5 %FS
LSB Value 2.44 mV 0...10 Vvoltage, 4.88 mV - 10...10 Vvoltage, 4.88 µA 0...20 mAcurrent, 3.91 µA 4...20 mAcurrent, 0.1 °Ctemperature probe, 0.1 °Cthermocouple
Conversion Time 100 ms + 100 ms per channel + 1 controller cycle time for analogue input thermocouple, 100 ms + 100 ms per channel + 1 controller cycle time for analogue input temperature probe, 10 ms + 10 ms per channel + 1 controller cycle time for analogue input voltage/current
Resistance To Conducted Disturbances 10 V 0.15...80 MHz conforming to EN/IEC 61000-4-6, 3 V spot frequency (2, 3, 4, 6.2, 8.2, 12.6, 16.5, 18.8, 22, 25 MHz) conforming to Marine specification (LR, ABS, DNV, GL)
Non-Linearity +/- 0.2 %FS
Absolute Accuracy Error +/- 0.2 % of full scale at 25 °C for analogue input voltage/current, +/- 0.2 % of full scale at 25 °C for Pt 100/Pt 1000, Ni 100/ Ni 1000 temperature probe, +/- 0.2 % of full scale at 25 °C for thermocouple C 0...2315 °C, +/- 6 °C at 25 °C for thermocouple R, S 0...200 °C, +/- 0.2 % of full scale at 25 °C for thermocouple R, S 200...1760 °C, +/- 0.2 % of full scale at 25 °C for thermocouple B 300...1820 °C, +/- 0.4 % of full scale at 25 °C for thermocouple K - 200...0 °C, +/- 0.2 % of full scale at 25 °C for thermocouple K 0...1300 °C, +/- 0.4 % of full scale at 25 °C for thermocouple J - 200...0 °C, +/- 0.2 % of full scale at 25 °C for thermocouple J 0...1000 °C, +/- 0.4 % of full scale at 25 °C for thermocouple E - 200...0 °C, +/- 0.2 % of full scale at 25 °C for thermocouple E 0...800 °C, +/- 0.4 % of full scale at 25 °C for thermocouple T - 200...0 °C, +/- 0.2 % of full scale at 25 °C for thermocouple T 0...400 °C, +/- 0.4 % of full scale at 25 °C for thermocouple N - 200...0 °C, +/- 0.2 % of full scale at 25 °C for thermocouple N 0...1300 °C
Cross Talk <= 1 LSB
Resistance to Magnetic Fields 30 A/m conforming to EN/IEC 61000-4-8
Sampling Duration 10 ms, analogue input type: voltage/current, 100 ms, analogue input type: voltage/current, 100 ms, analogue input type: thermocouple, 100 ms, analogue input type: temperature probe
Permissible Continuous Overload 13 V, analogue input type: voltage, 40 mA, analogue input type: current
Vibration Resistance 3.5 mm at 5-8.4 Hz on DIN rail, 3 gn at 8.4-150 Hz on DIN rail
Ambient Air Temperature For Operation -10-55 °C horizontal installation, -10-35 °C vertical installation
Standards EN/IEC 61010-2-201, EN/IEC 61131-2
Local Signalling 1 LED (green) for PWR
Electrical Connection 10 x 1.5 mm² removable screw terminal block with pitch 3.81 mm adjustment for inputs and supply, 10 x 1.5 mm² removable screw terminal block with pitch 3.81 mm adjustment for inputs
Input Impedance <= 50 Ohm current, >= 1 MOhm voltage, >= 1 MOhm thermocouple, >= 1 MOhm temperature probe
Storage Altitude 0-3000 m
Insulation Between input and supply at 1500 V AC, between input and internal logic at 500 V AC
Load Type Resistive
Type of Cable Twisted shielded pairs cable <30 m for input circuit
Range Compatibility Modicon M221, Modicon M241, Modicon M251, Modicon M262
Ambient Air Temperature For Storage -25-70 °C
Weight 0.1 kg