Brand : Schneider Electric
Item Name : Logic Controller
Model : TM221CE16R
Resistance To Electrostatic Discharge : 8 kV in air conforming to EN/IEC 61000-4-2, 4 kV on contact conforming to EN/IEC 61000-4-2
Depth : 70 mm
Supply Voltage Limits : 85-264 V
Discrete Output Current : 2A
Width : 95 mm
Supply : (serial)Serial link supply: 5 V, <200 mA
Data Backed Up : 256 kB built-in flash memory for backup of application and data
Data Storage Equipment : 2 GB SD card (optional)
Reset Time : 1 s
Clock Drift : <= 30 s/month at 25-25 °C
Discrete Output Current : 2 A
Discrete Input Current : 7 mA for discrete input, 5 mA for fast input
Voltage State 1 Guaranteed : >= 15 V for input
Immunity To Microbreaks : 10 ms
Discrete Input Voltage : 24 V
Backup Time : 1 year at 25 °C (by interruption of power supply)
Voltage State 0 Guaranteed : <= 5 V for input
Discrete Input Number : 9, discrete input conforming to IEC 61131-2 Type 1
Resistance To Electromagnetic Fields : 10 V/m 80 MHz...1 GHz conforming to EN/IEC 61000-4-3, 3 V/m 1.4 GHz...2 GHz conforming to EN/IEC 61000-4-3, 1 V/m 2...2.7 GHz conforming to EN/IEC 61000-4-3
Surge Withstand : 2 kV power lines (AC) common mode conforming to EN/IEC 61000-4-5, 2 kV relay output common mode conforming to EN/IEC 61000-4-5, 1 kV I/O common mode conforming to EN/IEC 61000-4-5, 1 kV shielded cable common mode conforming to EN/IEC 61000-4-5, 0.5 kV power lines (DC) differential mode conforming to EN/IEC 61000-4-5, 1 kV power lines (AC) differential mode conforming to EN/IEC 61000-4-5, 1 kV relay output differential mode conforming to EN/IEC 61000-4-5, 0.5 kV power lines (DC) common mode conforming to EN/IEC 61000-4-5
Resistance To Fast Transients : 2 kV (power lines) conforming to EN/IEC 61000-4-4, 2 kV (relay output) conforming to EN/IEC 61000-4-4, 1 kV (I/O) conforming to EN/IEC 61000-4-4, 1 kV (Ethernet line) conforming to EN/IEC 61000-4-4, 1 kV (serial link) conforming to EN/IEC 61000-4-4
Electromagnetic Emission : Conducted emissions - test level: 79 dBμV/m QP/66 dBμV/m AV ( power lines (AC)) at 0.15-0.5 MHz conforming to EN/IEC 55011, conducted emissions - test level: 73 dBμV/m QP/60 dBμV/m AV ( power lines (AC)) at 0.5-300 MHz conforming to EN/IEC 55011, conducted emissions - test level: 120...69 dBµV/m QP ( power lines) at 10-150 kHz conforming to EN/IEC 55011, conducted emissions - test level: 63 dBμV/m QP ( power lines) at 1.5-30 MHz conforming to EN/IEC 55011, radiated emissions - test level: 40 dBμV/m QP class A ( 10 m) at 30-230 MHz conforming to EN/IEC 55011, conducted emissions - test level: 79...63 dBμV/m QP ( power lines) at 150-1500 kHz conforming to EN/IEC 55011, radiated emissions - test level: 47 dBμV/m QP class A ( 10 m) at 200-1000 MHz conforming to EN/IEC 55011
Permitted Overload On Inputs : +/- 30 V DC for 5 min (maximum) for analog input, +/- 13 V DC (permanent) for analog input
Discrete Output Type : Relay normally open
Analogue Input Resolution : 10 bits
LSB Value : 10 mV
Conversion Time : 1 ms per channel + 1 controller cycle time for analogue input analog input
Sensor Power Supply : 24-24 V DC at 250 mA supplied by the controller
Realtime Clock : With
Analogue Input Number : 2 at 0...10 V
Discrete Output Number : 8 relay
Realtime Clock : With
Discrete Input Logic : Sink or source (positive/negative)
Discrete Input Voltage Type : DC
Maximum Number Of I/O Expansion Module : 4 for transistor output, 4 for relay output
Counting Input Number : 4 fast input (HSC mode) at 100 kHz 32 bits
Resistance To Conducted Disturbances : 10 V 0.15...80 MHz conforming to EN/IEC 61000-4-6, 3 V 0.1...80 MHz conforming to Marine specification (LR, ABS, DNV, GL), 10 V spot frequency (2, 3, 4, 6.2, 8.2, 12.6, 16.5, 18.8, 22, 25 MHz) conforming to Marine specification (LR, ABS, DNV, GL)
Maximum Cable Distance Between Devices : Shielded cable: <10 m for fast input, unshielded cable: <30 m for output, unshielded cable: <30 m for digital input, unshielded cable: <1 m for analog input, shielded cable: <3 m for fast output
Transmission Rate : 1.2...115.2 kbit/s (115.2 kbit/s by default) for bus length of 15-15 m for RS485, 1.2...115.2 kbit/s (115.2 kbit/s by default) for bus length of 3-3 m for RS232, 480 Mbit/s for USB
Discrete I/O Number : 16
Configurable Filtering Time : 0 ms for input, 3 ms for input, 12 ms for input
Maximum Current Per Output Common : 6 A at COM 1, 7 A at COM 0
Application Structure : 8 interrupt tasks, 1 cyclic auxiliary task, 1 configurable freewheeling/cyclic master task
Discrete Output Voltage : 5...125 V DC, 5...250 V AC
Memory Capacity : 256 kB for user application and data RAM with 10000 instructions, 256 kB for internal variables RAM
Execution Time For 1 KInstruction : 0.3 ms for event and periodic task
Absolute Accuracy Error : +/- 1 % of full scale for analog input
Resistance To Magnetic Fields : 30 A/m 50/60 Hz conforming to EN/IEC 61000-4-8
Port Ethernet : 10BASE-T/100BASE-TX 1 port with 100 m copper cable
Maximum Power Consumption in VA : 49 VA at 100...240 V with max number of I/O expansion module, 33 VA at 100...240 V without I/O expansion module
Communication Service : DHCP client, Ethernet/IP adapter, Modbus TCP server, Modbus TCP slave device, Modbus TCP client
Regulation Loop : Adjustable PID regulator up to 14 simultaneous loops
Exct Time For Event Task : 60 µs response time
Execution Time Per Instruction : 0.2 µs Boolean
Maximum Size Of Object Areas : 255 %C counters, 512 %KW constant words, 255 %TM timers, 512 %M memory bits, 8000 %MW memory words
Minimum Load : 1 mA at 5 V DC for relay output
Vibration Resistance : 3.5 mm at 5-8.4 Hz on symmetrical rail, 3.5 mm at 5-8.4 Hz on panel mounting, 1 gn at 8.4-150 Hz on symmetrical rail, 1 gn at 8.4-150 Hz on panel mounting
Ambient Air Temperature For Operation : -10-55 °C (horizontal installation), -10-35 °C (vertical installation)
Standards : EN/IEC 61010-2-201, EN/IEC 60664-1, EN/IEC 61131-2
Communication Port Protocol : USB port: USB - SoMachine-Network, non isolated serial link: Modbus master/slave - RTU/ASCII or SoMachine-Network, Ethernet
Control Signal Type : Pulse/direction, single phase, A/B
Switching Frequency : 20 switching operations/minute with maximum load
Storage Altitude : 0-3000 m
Electrical Durability : 100000 cycles AC-12, 120 V, 240 VA, resistive, 100000 cycles AC-14, cos phi = 0.7 , 240 V, 240 VA, inductive, 300000 cycles AC-14, cos phi = 0.7 , 120 V, 36 VA, inductive, 300000 cycles AC-14, cos phi = 0.7 , 240 V, 72 VA, inductive, 100000 cycles DC-12, 24 V, 48 W, resistive, 300000 cycles DC-12, 24 V, 16 W, resistive, 100000 cycles DC-13, 24 V, 24 W, inductive (L/R = 7 ms), 300000 cycles DC-13, 24 V, 7.2 W, inductive (L/R = 7 ms), 100000 cycles AC-12, 240 V, 480 VA, resistive, 300000 cycles AC-12, 120 V, 80 VA, resistive, 300000 cycles AC-12, 240 V, 160 VA, resistive, 100000 cycles AC-15, cos phi = 0.35 , 120 V, 60 VA, inductive, 100000 cycles AC-15, cos phi = 0.35 , 240 V, 120 VA, inductive, 300000 cycles AC-15, cos phi = 0.35 , 120 V, 18 VA, inductive, 300000 cycles AC-15, cos phi = 0.35 , 240 V, 36 VA, inductive, 100000 cycles AC-14, cos phi = 0.7 , 120 V, 120 VA, inductive
Ambient Air Temperature For Storage : -25-70 °C