Brand:Schneider Electric
Collections:Electricals
Type:Emergency Stop Head
Description

    Schneider Electric XB5AT842 Red Ø40 Emergency Stop Head, also called EMS (Emergency Machine Stop) and EMO (Emergency Off), installs easily into standard 22mm diameter cutouts and connects with simple screw terminal connections. It is clearly visible from a distance thanks to its light color and distinctive 40mm mushroom shape.

    Thanks to IP66, it is shock, dust, water and vibration resistant, making it ideal for use in harsh environments. Thanks to its plastic cover, it is ideal for applications that require good chemical resistance and/or double electrical insulation.

    Features
    • Operates with a push-pull mechanism. 
    • Ideal for use in harsh environments
    • Shock, dust, water and vibration resistant
Specifications

    Brand : Schneider Electric

    Item Name : Head For Emergency Stop Push-Button

    Model : XB5AT842

    Conventional Free Air Thermal Current : 10 A conforming to EN/IEC 60947-5-1

    Rated Insulation Voltage : 600 V (pollution degree 3) conforming to EN 60947-1

    Rated Impulse Withstand Voltage : 6 kV conforming to EN 60947-1

    Bezel Material : Dark Grey Plastic

    Cap/Operator Or Lens Color : Red

    Compatibility Code : ZB5

    Connections - Terminals : Screw clamp terminals, <= 2 x 1.5 mm² with cable end conforming to EN 60947-1, screw clamp terminals, >= 1 x 0.22 mm² without cable end conforming to EN 60947-1

    Contact Operation : Slow-break

    Contacts Material : Silver alloy (Ag/Ni)

    Depth : 82 mm

    Electrical Reliability : λ < 10exp(-6) at 5 V, 1 mA in clean environment conforming to EN/IEC 60947-5-4, λ < 10exp(-8) at 17 V, 5 mA in clean environment conforming to EN/IEC 60947-5-4

    Fixing Collar Material : Plastic

    Height : 43 mm

    IK Degree Of Protection : IK03 conforming to IEC 50102

    IP Degree Of Protection : IP66 conforming to IEC 60529, IP67, IP69, IP69K

    Marking : Unmarked

    Mechanical Durability : 300000 cycles

    Mounting Diameter : 22 mm

    Operator Profile : Red Mushroom Ø 40 mm, unmarked

    Overvoltage Category : Class II conforming to IEC 60536

    Certifications : CSA, DNV, BV, UL listed, GL, LROS (Lloyds register of shipping)

    Positive Opening : With conforming to EN/IEC 60947-5-1 appendix K

    Protective Treatment : TH

    Range Of Product : Harmony XB5

    Reset : Push-Pull

    Sale Per Indivisible Quantity : 1

    Shape of Signaling Unit Head : Round

    Shock Resistance : 30 gn (duration = 18 ms) for half sine wave acceleration conforming to IEC 60068-2-27, 50 gn (duration = 11 ms) for half sine wave acceleration conforming to IEC 60068-2-27

    Short-Circuit Protection : 10 A cartridge fuse type gG conforming to EN/IEC 60947-5-1

    Terminals Description : ISO n°1 (11-12)NC

    Tightening Torque : 0.8-1.2 N.m conforming to EN 60947-1

    Type of Operator : Trigger Action and mechanical latching

    Width : 40 mm

    NEMA Degree Of Protection : NEMA 13, NEMA 4X

    Group Of Product : Emergency stop turn to release

    Customizable : 0

    Head Type : Standard

    Resistance To High Pressure Washer : 7000000 Pa at 55 °C, distance : 0.1 m

    Contacts Usage : Standard contacts

    Operating Travel : 1.5 mm (NC changing electrical state), 4.3 mm (total travel)

    Station Name : XALD 1 cut-out, XALK 1 cut-out

    Vibration Resistance : 5 gn (f= 2-500 Hz) conforming to IEC 60068-2-6

    Ambient Air Temperature For Operation : -40-70 °C

    Ambient Air Temperature For Storage : -40-70 °C

    Standards : EN/IEC 60947-5-4, IEC 60364-5-53, EN/IEC 60204-1, EN/ISO 13850, EN/IEC 60947-5-1, JIS C8201-5-1, EN/IEC 60947-1, UL 508, CSA C22.2 No 14, EN/IEC 60947-5-5, JIS C8201-1

    Rated Operational Current : 3 A at 240 V, AC-15, A600 conforming to EN/IEC 60947-5-1, 6 A at 120 V, AC-15, A600 conforming to EN/IEC 60947-5-1, 0.1 A at 600 V, DC-13, Q600 conforming to EN/IEC 60947-5-1, 0.27 A at 250 V, DC-13, Q600 conforming to EN/IEC 60947-5-1, 0.55 A at 125 V, DC-13, Q600 conforming to EN/IEC 60947-5-1, 1.2 A at 600 V, AC-15, A600 conforming to EN/IEC 60947-5-1

    Electrical Durability : 1000000 cycles, AC-15, 2 A at 230 V, operating rate <3600 cyc/h, load factor: 0.5 conforming to EN/IEC 60947-5-1 appendix C, 1000000 cycles, AC-15, 3 A at 120 V, operating rate <3600 cyc/h, load factor: 0.5 conforming to EN/IEC 60947-5-1 appendix C, 1000000 cycles, AC-15, 4 A at 24 V, operating rate <3600 cyc/h, load factor: 0.5 conforming to EN/IEC 60947-5-1 appendix C, 1000000 cycles, DC-13, 0.2 A at 110 V, operating rate <3600 cyc/h, load factor: 0.5 conforming to EN/IEC 60947-5-1 appendix C, 1000000 cycles, DC-13, 0.5 A at 24 V, operating rate <3600 cyc/h, load factor: 0.5 conforming to EN/IEC 60947-5-1 appendix C

    Device Presentation : Complete Product

    Weight : 0.065 kg